Home/Lessons/Lesson 12

Heat Engines and Refrigerators

Keywords: Heat engines, Open systems, Enthalpy balances, Coefficient of performance, Vapor-compression cycle, Rankine cycle, Open Brayton cycle, Turbines and compressors, Isentropic efficiency, Combined cycle

Revision in progress

Thermodynamics was born from the steam engine, and it is with the steam engine that we will conclude our study of it. In Lesson 6, we established Carnot's theorems: the efficiency of a two-reservoir engine cannot exceed , and this bound is reached only by reversible machines. At that point, however, we reasoned about abstract machines exchanging heat with two ideal thermal reservoirs. How does a power plant, a refrigerator or a jet engine actually work? Why is their efficiency so far below the Carnot bound, and how do engineers get closer to it?

To answer these questions, we will need almost everything we have learned so far. The working fluid of a steam engine changes phase during its cycle, and Lesson 11 will allow us to follow these changes in the diagram. The enthalpy of Lesson 10 will play a central role. One tool is still missing, however: the energy balance of an open system, through which matter flows, since this is how a turbine, a pump or a compressor operates. We will establish it along the way.

We keep the banker's sign convention of Lesson 4: the heat and work received by the fluid are counted as positive. A turbine supplies work, and therefore receives negative work; a pump or a compressor receives positive work.

1. Engines, refrigerators and heat pumps

1.1. The steam engine

The best-known steam engine, that of the old locomotives, did not really operate in a cycle: the steam that had pushed the pistons was simply released into the air, and the trains had to stop regularly to refill with water. It is possible, however, to circulate the water in a closed loop; the only thing that then needs to be replenished is the fuel, which serves as the heat source. This is how thermal power plants work today, whether they burn coal or gas or use the heat released by nuclear fission.

The principle is as follows. In the boiler, the heat source vaporizes water at high pressure: the water receives heat. The steam then expands in a turbine, turning its blades; this motion drives an alternator, and the water thus supplies work to the surroundings. The low-pressure steam leaving the turbine is then liquefied in the condenser, in contact with a cold reservoir, the water of a river or the air of a cooling tower: the water gives up heat. Finally, a pump returns the liquid water at high pressure to the boiler, which requires supplying it with a small amount of work. The water, which goes through this cycle indefinitely, is called the working fluid.

Over a complete cycle, the fluid returns to its initial state and its internal energy is unchanged. The first law therefore gives

where is the heat received in the boiler, the heat received in the condenser, and the net work received, which combines the work supplied by the turbine and the smaller work received by the pump. The efficiency of Lesson 6,

measures the fraction of the heat supplied by the fuel that is converted into work. The second law requires : part of the heat must necessarily be rejected to the cold reservoir.

1.2. The refrigerator and the heat pump

A refrigerator operates in reverse: it receives work in order to extract heat from the cold compartment and reject it into the room. You can check this at home: the metal grille at the back or on the sides of the refrigerator is warm. It is a heat exchanger, the condenser, through which the heat extracted from the food is discharged into the kitchen. The same machine, on a larger scale, is also used to heat houses: this is the heat pump, which extracts heat from the outside air, or from the ground, and delivers it to the inside of the building.

For these machines, we do not speak of efficiency but of the coefficient of performance, or COP, the ratio of the useful effect to the work expended. The useful effect is not the same in the two cases: for a refrigerator, it is the heat extracted from the cold reservoir; for a heat pump, it is the heat delivered to the hot reservoir. We therefore define

where the last equality follows from the first law, . Unlike an efficiency, a COP can be, and generally is, greater than one. This in no way violates energy conservation: a heat pump does not create heat, it moves heat that already exists outside, and the work serves only to force this transfer from cold to hot.

As for the engine, the second law bounds these coefficients. Over a cycle, the entropy of the fluid returns to its initial value, and the Clausius inequality of Lesson 6 gives . Combined with the first law, it leads to

(exercise: check this), with equality for a reversible machine. These bounds show that the cost of a heat transfer grows rapidly with the temperature difference to be overcome. For a heat pump that heats a floor to by drawing on the outside air at , the bound is ; real machines achieve COPs of the order of to . This is already much better than an electric heater, whose “COP” is exactly one.

Remark 1
Does a refrigerator with its door left open cool the kitchen? See the exercise “Does an open refrigerator cool the room?”.

2. The energy balance of an open system

2.1. The control volume

A turbine, a pump, a boiler or a condenser is permanently traversed by a flow of fluid. The first law as we stated it in Lesson 4 cannot be applied to them directly, since it concerns closed systems. To study them, we delimit a region of space called a control volume, for example the interior of the turbine. Its boundary is fixed, but matter crosses it: it enters through an inlet section, denoted in, and leaves through an outlet section, denoted out.

To apply the first law nonetheless, let us return to a closed system. Consider, at time , the fluid contained in the control volume, to which we add the small mass about to enter it during the time interval . At time , this same body of matter consists of the fluid contained in the control volume and a mass that has just left it. We assume steady state: the state of the fluid at each point of the control volume does not depend on time, and as much matter enters as leaves.

Since the content of the control volume is the same at both times, the change in energy of the closed system reduces to the difference between the energy of the mass that has left and that of the mass that has entered. Each kilogram carries its specific internal energy , its kinetic energy , where is the flow velocity, and its gravitational potential energy . Thus,

What work does the closed system receive? First, there is the work exchanged with the moving parts of the machine, the turbine blades or the pump rotor: this is the useful work, or “indicated” work. But there is also the work of the pressure forces exerted by the surrounding fluid. At the inlet, the upstream fluid pushes the mass , of volume , at pressure : it supplies it with the work . At the outlet, the system must instead push back the downstream fluid, and receives the work . This work required to make matter enter and leave is called flow work.

The first law applied to the closed system then reads . Grouping the flow-work terms with the internal energy, we see the specific enthalpy of Lesson 10 appear. Finally, dividing by and denoting by the mass flow rate, and by and the thermal and mechanical power received, we obtain

(1)

This is the first law for an open system in steady state. We now see why enthalpy is the natural quantity for flows: the term represents the work that must be supplied to push each kilogram of fluid through the machine.

In the machines we will study, changes in kinetic and potential energy are generally negligible compared with changes in enthalpy. Dividing by the flow rate, we then obtain the very simple form that we will use constantly, for the heat and the useful work received per kilogram of fluid:

(2)

2.2. The entropy balance

The same reasoning applies to entropy. For an adiabatic component, which exchanges no heat, the second law applied to the closed system above requires the entropy of the mass that has left to be at least equal to that of the mass that has entered:

with equality if the flow is reversible. An ideal turbine or pump, adiabatic and reversible, is therefore isentropic. Real machines produce entropy, through viscous friction or turbulence, and their outlet has a higher entropy.

An important special case is that of a valve, or a simple constriction in the pipe, in which the fluid expands without exchanging either heat or work. The balance (2) then gives : the expansion is isenthalpic. It is also highly irreversible, since no work is recovered. This is the Joule-Thomson expansion, which plays an essential role in refrigerators.

3. The Rankine cycle

3.1. Why a phase change?

Why use water that vaporizes and condenses, rather than a gas that would remain gaseous? The reason is related to Carnot's theorems. To approach the maximum efficiency, heat must be received at the highest possible temperature and rejected at the lowest possible temperature, at constant temperatures. Now, we saw in Lesson 11 that a phase change at constant pressure takes place precisely at constant temperature. Vaporization in the boiler and liquefaction in the condenser therefore naturally realize the two isotherms of the Carnot cycle. Moreover, latent heats are very large: a kilogram of vaporizing water absorbs a considerable amount of energy, which makes compact machines possible.

One could then imagine a Carnot cycle located entirely under the saturation dome, with two reversible adiabats connecting the two phase-change plateaus. But the adiabatic compression would then have to compress a mixture of liquid and vapor, which is technically very difficult. In the mid-nineteenth century, the Scottish engineer William Rankine proposed moving this compression to after complete condensation: the pump then compresses only a liquid. A liquid has a very small specific volume, so the pump work remains small.

3.2. The cycle in the diagram

Let us first recall the vocabulary of Lesson 11. In the pressure – specific volume diagram, the region where the liquid and its vapor coexist is bounded by the saturation dome. Its left part, the bubble-point curve, is the locus of saturated liquids, ready to form their first bubble; its right part, the dew-point curve, is the locus of saturated vapors, ready to form their first droplet. The two curves meet at the critical point. Inside the dome, the lever rule gives the vapor mass fraction, or quality, , from which all the specific quantities of the mixture can be expressed. Denoting the saturated liquid by the subscript and the saturated vapor by the subscript , at the same pressure,

Ideal Rankine cycle in the (P,v) diagram. The representation is qualitative: the volume scale is strongly compressed on the liquid side to make the pump and the bubble-point curve visible.
Figure 1. Ideal Rankine cycle in the diagram. The representation is qualitative: the volume scale is strongly compressed on the liquid side to make the pump and the bubble-point curve visible.

The ideal Rankine cycle consists of four steps, shown in Figure 1:

  1. : reversible adiabatic compression of the liquid by the pump, from the low pressure to the high pressure ;
  2. : heating of the liquid, vaporization, then superheating of the vapor at constant pressure in the boiler;
  3. : reversible adiabatic expansion of the vapor in the turbine;
  4. : complete liquefaction at constant pressure in the condenser.

The cycle is traversed clockwise: as we saw in Lesson 5, it is a power cycle, whose area represents the net work supplied.

3.3. Calculating the cycle, component by component

Let us apply the balance (2) to each of the four components, starting from the saturated liquid leaving the condenser.

The pump, .

It is adiabatic and reversible, hence isentropic. The fundamental relation written in terms of enthalpy, , then reduces to . Since the liquid is nearly incompressible, its specific volume remains approximately equal to , and

Since the specific volume of a liquid is very small, this work is small.

The boiler, .

It supplies no work, and

This heat comprises heating the liquid up to the boiling temperature, the latent heat of vaporization, and then the superheating of the vapor.

The turbine, .

It is adiabatic and reversible, so . It receives the work ; in other words, it supplies the positive work

In general, state lies under the dome. Its quality follows from entropy conservation, and its enthalpy then from the lever rule:

where the saturation properties are taken at the low pressure .

The condenser, .

It supplies no work and receives the heat : it rejects per kilogram.

Adding these four balances, all the enthalpies cancel, and we recover the cycle balance, . The efficiency of the cycle is

(3)

The whole calculation thus comes down to determining the enthalpies at four points. These cannot be calculated with a simple model: water is neither an ideal gas nor an incompressible liquid over the whole cycle. They are read from steam tables, constructed from measurements of heat capacities and from equations of state, as we explained in Lesson 9.

3.4. Comparison with the Carnot bound

Consider a typical cycle operating between kPa, a pressure at which water liquefies at about , and MPa, with steam superheated to at the turbine inlet. Using steam tables, the calculation yields an efficiency of about , and a pump work of barely one percent of the turbine work. Between the same extreme temperatures, K and K, the Carnot efficiency would be . Why such a gap, when the ideal cycle is reversible?

The answer is that the fluid does not receive all its heat at K. A large part is received at lower temperature, while the liquid is being heated and during vaporization, which takes place at at MPa. This can be quantified by defining a mean temperature of heat addition. Since the boiler operates at constant pressure, , and we set

Heat, on the other hand, is rejected at the constant temperature of the condenser, and . Since the pump and the turbine are isentropic, , and the efficiency can be written exactly as

The ideal Rankine cycle therefore has the efficiency of a Carnot cycle that would receive all its heat at the mean temperature . In our example, K only, hence . To improve the efficiency, the main goal is therefore to raise the mean temperature at which heat is received. This is the common thread running through all the improvements of the modern steam engine.

Remark 3
To carry out the complete calculation with the tables, see the exercise “Rankine cycle with steam”.

4. Improving the steam engine

4.1. Superheating and reheating

The previous calculation reveals another problem: at the turbine outlet, the vapor quality is only about . One fifth of the mass of the fluid thus consists of water droplets, which strike the blades at high speed and eventually erode them. Superheating the steam at the turbine inlet moves point to the right and keeps the end of the expansion away from the wet region; at the same time, it raises the mean temperature of heat addition, and hence the efficiency.

But the maximum temperature is limited by the strength of the steels used in the boiler and the blades. To go further, the expansion is interrupted at an intermediate pressure and the steam is sent back to the boiler to be heated again: this is reheating, shown in Figure 2.

Rankine cycle with reheat. The steam first expands in the high-pressure turbine, returns to the boiler, and then expands in the low-pressure turbine. Both turbines drive the same alternator.
Figure 2. Rankine cycle with reheat. The steam first expands in the high-pressure turbine, returns to the boiler, and then expands in the low-pressure turbine. Both turbines drive the same alternator.

Let denote the inlet of the high-pressure turbine, its outlet, the outlet of the reheater and the outlet of the low-pressure turbine. The same balances give

(4)

The primary purpose of reheating is to keep the steam sufficiently dry during the second expansion. Its effect on the efficiency depends on the chosen pressures and temperatures, but it is generally favorable, because the additional heat is received at high temperature.

4.2. Regeneration and supercritical cycles

One can also avoid heating in the boiler the still cold water leaving the pump, since this is the part of the heat that is received at the lowest temperature. In a regenerative cycle, a small fraction of the steam is bled from an intermediate stage of the turbine and used to preheat the water returning to the boiler. This extracted steam no longer supplies work in the last part of the turbine, but the boiler receives water that is already hot: the mean temperature of heat addition increases, and so does the efficiency.

Finally, the most modern power plants operate above the critical point of water, MPa and K [1]. There is then no longer a vaporization plateau in the boiler: as we saw in Lesson 11, the fluid passes continuously from a dense, liquid-like state to a vapor-like state. The heat is no longer received largely at the vaporization temperature, and the mean temperature of heat addition increases further. The return to the condenser, however, still takes place under the saturation dome.

4.3. Actual efficiencies

In a real power plant, the turbines and pumps are not reversible, heat exchanges take place across finite temperature differences, and auxiliary equipment consumes part of the work produced. The actual efficiency is therefore well below the Carnot bound. A few orders of magnitude help to place these machines:

  • a pressurized water nuclear power plant converts into electricity about one third of the thermal power produced by the reactor, between and depending on the unit [2];
  • a modern coal-fired power plant reaches about , and the most advanced supercritical plants aim for the mid-forties [3].

The lower efficiency of nuclear power plants is largely explained by a deliberately lower steam temperature, for reasons of safety and of the resistance of the reactor materials. The second law then imposes a more stringent bound, however good the turbine. These figures also mean that two thirds of the energy produced by a reactor are rejected as heat, into a river, into the sea, or into the atmosphere through cooling towers.

Finally, note that these values depend on the conventions adopted, such as the choice between gross and net efficiency, or the temperature of the cold reservoir. A single value should therefore not be compared to within a percentage point.

5. The vapor-compression refrigeration cycle

Let us return to the refrigerator. Its cycle also uses a fluid that changes phase, but traversed in the refrigeration direction. The refrigerant is not water, but a substance chosen for its thermodynamic properties, in particular for boiling at low temperature under reasonable pressures. Older refrigerators used chlorofluorocarbons, the “freons”, banned since the 1987 Montreal Protocol because they destroy the ozone layer. Today's domestic refrigerators often use isobutane.

The cycle comprises four steps, which can be followed starting from the cold fluid circulating inside the refrigerator:

  1. , in the evaporator, inside the compartment: the fluid, a mixture of liquid and vapor at low pressure and low temperature, extracts heat from the compartment and vaporizes completely;
  2. , in the compressor, outside: the vapor is compressed and leaves at high pressure and high temperature. It is the electrically powered compressor that is responsible for the characteristic hum of the refrigerator;
  3. , in the condenser, the grille at the back: the hot vapor gives up heat to the room and liquefies;
  4. , in the expansion device: the high-pressure liquid passes through a constriction, a capillary tube or a valve, and its pressure drops abruptly. Part of the liquid vaporizes, which cools the mixture: the fluid reaches the coldest state of the cycle, and the cycle starts again.

The balance (2), applied to each component, gives

the last equality expressing the isenthalpic expansion in the expansion device. The coefficient of performance of the refrigerator is therefore

(5)

The expansion device is the main source of irreversibility in the ideal cycle: recovering the expansion work, which would be very small, is given up for the sake of simplicity. This is one of the reasons why the COP of a real refrigerator, of the order of to , remains well below the reversible bound, which is about between a freezer at and a kitchen at around the condenser.

6. Open cycles

6.1. The gas turbine

A gas turbine, such as those fitted to aircraft or used in some power plants, operates in open flow: it draws in air, compresses it, burns a fuel in it, and then expands the hot gases in a turbine before discharging them into the atmosphere. Each mass of air therefore passes through the machine only once, and the fluid does not describe a cycle. To calculate it, however, it is modeled by a fictitious closed cycle, the Brayton cycle, in which combustion is replaced by heat addition at constant pressure and the exhaust of the gases by cooling at constant pressure.

The balance (2) gives the work received by the compressor, , the heat received in the combustion chamber, , and the work supplied by the turbine, . The net work is positive only if the turbine supplies more work than the compressor consumes, which is possible because it expands a much hotter gas, and hence one of larger volume. For an ideal gas with constant heat capacities, with isentropic compression and expansion, Laplace's laws from Lesson 5 lead to the efficiency

which increases with the pressure ratio . But the turbine inlet temperature is limited by the strength of the blades, and, for a fixed maximum temperature, too high a pressure ratio eventually reduces the net work. A simple gas turbine typically converts to of the fuel energy into electricity [4]. Its exhaust gases therefore still leave very hot, at several hundred degrees.

6.2. The combined cycle

These hot exhaust gases constitute a perfectly usable heat source. In a combined-cycle power plant, they pass through a heat recovery boiler, which produces the steam for a Rankine cycle driving a second turbine (Figure 3).

Combined-cycle power plant. The gas turbine supplies a first share of the power, then its exhaust gases heat a heat recovery boiler that feeds a steam cycle and a second turbine.
Figure 3. Combined-cycle power plant. The gas turbine supplies a first share of the power, then its exhaust gases heat a heat recovery boiler that feeds a steam cycle and a second turbine.

If the gas turbine converts a fraction of the fuel energy into work, it rejects in its exhaust gases. If the steam cycle in turn converts a fraction of this heat, the total work is , and the overall efficiency is

(6)

With and , we already obtain . When it was commissioned in 2016, the Bouchain combined-cycle power plant, in northern France, demonstrated a net efficiency of [5]. This is one of the highest efficiencies ever achieved by a thermal power plant. It in no way contradicts the Carnot bound: it simply uses the high-temperature heat first, and then the residual heat at a lower temperature, before the final rejection.

7. Summary

Key point (Studying a heat engine)
  1. Define the system, and specify whether it is closed or traversed by a flow.
  2. Place the successive states of the fluid on a diagram, locating the saturation dome if the fluid changes phase.
  3. Write, component by component, the balance , and use isentropy for ideal pumps, compressors and turbines.
  4. Read the enthalpies from the tables, then calculate the efficiency or the COP, and compare it with the Carnot bound.

All these machines obey the same laws. The first law fixes the energy balance, which is naturally written in terms of enthalpy for flows. The second law requires part of the heat to be rejected to the cold reservoir, and sets the Carnot bound. Engineers therefore do not try to get around this bound, but to approach it: by receiving heat at the highest possible mean temperature, rejecting it at the lowest, and reducing irreversibilities.

8. References

  1. International Association for the Properties of Water and Steam, Guideline on the Use of Fundamental Physical Constants and Basic Constants of Water, current revision.
  2. International Atomic Energy Agency, Efficient Water Management in Water Cooled Reactors, IAEA Nuclear Energy Series NP-T-2.6 (2012).
  3. Mitsubishi Heavy Industries, Technical Development and Future Prospect of Advanced Ultra-Supercritical Steam Power Generation (2011).
  4. U.S. Department of Energy, How Gas Turbine Power Plants Work.
  5. GE Vernova, 9HA.01 Sets Efficiency World Record: EDF Bouchain, demonstrated net combined-cycle efficiency 62.22 percent.